Broadcast SRC-32 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Controlos remotos Broadcast SRC-32. “HOW TO” SERIES - OMT Technologies Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 19
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
“HOW TO” SERIES
HOW TO INSTALL THE BROADCAST TOOLS GPI 32 WITH
LOGGER/ONAIR
NOVEMBER 2007
Vista de página 0
1 2 3 4 5 6 ... 18 19

Resumo do Conteúdo

Página 1 - “HOW TO” SERIES

“HOW TO” SERIES HOW TO INSTALL THE BROADCAST TOOLS GPI 32 WITH LOGGER/ONAIR NOVEMBER 2007

Página 2

COM port value that you have previously installed with the USB Serial device. Click at the bottom right corner of the workstation page then selec

Página 3

Show tally 1 as this was kept sequential to make it easy to remember which button position has been assigned what closure. Example of audio assign

Página 4

LOGGER CONFIGURATION Once the VCP software is installed (see previous driver setup), configuring Logger is relatively simple. Start the Logger appl

Página 5

Special Notes: Be sure to select “COM 1” on the SRC 32 under the Hardware device selection on versions 2.6.1 and older. Versions 2.6.2 and later wil

Página 6

TROUBLESHOOTING Log Tools software along with ONAIR full log display provides an effective way to verify your closures are configured and working c

Página 7

Out log example viewed through Reporter in Log Tools Enabling the Tally diagnostic can eliminates hours of troubleshooting and guesswork when trying

Página 8

Give an appropriate name for the connection such as TEST and click . Select the COM port you have the GPI 32 device connected to and click . B

Página 9

Force a closure at input 1 through 16 on the first block (J5) and 17 through 32 on the second block (J6) starting with the first connector position

Página 10

If you can see populating the field then you have verified the COM is working correctly. If the closures are not being recognized with a func

Página 11

For iMediaTouch system design and support: Rick Landry Support/Integration Manager [email protected] OMT Support 1-800-726-2635 To report

Página 12

OVERVIEW OMT Technologies is always searching and testing the latest in cost effective interfacing hardware with our software solutions to provide e

Página 13

INSTALLATION Please read the Broadcast Tools GPI 32 manual before installing this device as it will provide an outline of how the device functions

Página 14

hardware attached. You will require a USB Serial device driver and OMT Support have verified that Royalty Free drivers are available at: http://www.f

Página 15

Double click on Ports (COM & LPT) and verify there is a USB serial device driver installed. You may want to change the COM port that the new

Página 16

The following screen will allow you to select an open or available COM port in Windows. The above example is changing COM 3 to COM 2. After you

Página 17

Reboot the computer as the COM port will need to be reinitialized through Windows. Now you are ready to configure your Media Touch ONAIR or Logger

Página 18

ONAIR CONFIGURATION To configure the ONAIR application we will click on the iMediaTouch logo at the top right corner of the ONAIR main screen. You

Página 19

You will be prompted for a password. The default password is “omt” in lower case. If this password does not change the page you are currently on t

Comentários a estes Manuais

Sem comentários